Current - Issue

Conference Proceeding

Mechatronic Design and Robust Control of A Low-Cost Non- Invasive Artificial Ventilator Using STM Arm Controller with Vital Signs Monitoring (Ks6020)

Roopa N1 Dr.Naveen B2 Rakshitha J R3 Prabhavathi K4 Mohan Kumar V5 Deepak R6
1 3 5 Department of Electronics & Communication Engineering, BGS Institute of Technology, Mandya, Karnataka, India. 2 Professor, Department of Electronics & Communication Engineering, BGS Institute of Technology, Mandya, Karnataka, India 4 Associate Professor, Department of Electronics and Communication Engineering , BGS Institute of Technology, Mandya, Karnataka, India. 6 Assistant Professor, Department of Electronics and Communication Engineering, BGS Institute of Technology, Mandya, Karnataka, India.

Published Online: May-June 2026

Pages: 235-242

Cite this article

No DOI

Abstract

The timely accessibility of effective and reliable respiratory assistance systems is a key issue, especially in resource-constrained healthcare facilities. The conventional respirators being expensive and complicated in nature, as well as requiring trained professionals to operate, pose significant barriers in accessing care in many emergency and rural settings. Conventional manual ventilation is cumbersome, unreliable, and does not have the facility to monitor patients in real-time, thus posing safety risks under different situations. The objective of this research paper is to introduce a cost-effective artificial ventilator system utilizing embedded and mechatronics principles that is capable of providing effective respiratory assistance. The proposed artificial ventilator is controlled by the STM ARM microcontroller, which facilitates the control of airflow, pressure, and breathing cycles through the use of motorized ambu bags. Sensor modules, incorporating pressure, flow sensors, and the KS6020 module, ensure real-time monitoring of vital parameters like oxygen saturation (SpO₂), heart rate, and body temperature.The suggested solution further employs closed-loop control systems to ensure steady performance according to the changing needs of the patients. From the experimental findings, it can be concluded that the system provides a consistent flow of air into the lungs, monitors vital signs precisely, and responds effectively to any anomalies. This low- cost and portable artificial respirator can be employed in rural health care facilities and home health care scenarios for emergency purposes.

Related Articles

2026

AI-Based Stomach Cancer Detection Using Biomarkers, Medical Images, and Voice Analysis

2026

Hydrogen-Efficient Eco-Driving and Route Planning for Fuel-Cell Electric Vehicles Using Multi-Objective Optimization Under Traffic and Terrain Uncertainty

2026

A Data-Driven Machine Learning Framework for Assessing Patent Commercial Value and Technological Significance

2026

Evaluating Student Academic Performance Through a Benchmark of Fuzzy Reasoning Models

2026

A Hybrid Soft Computing Approach for Managing Uncertainty in Data Analytics

2026

Soft Computing Approaches for Robust Analysis of Imbalanced and Noisy Data

Share Article

X
LinkedIn
Facebook
WhatsApp

Or copy link

https://theijire.com/archives/mechatronic-design-and-robust-control-of-a-low-cost-non-invasive-artificial-ventilator-using-stm-arm-controller-with-vital-signs-monitoring-ks6020

*Instagram doesn't support direct link sharing from web. Copy the link and share it in your Instagram story or post.