ARCHIVES
Review Article
Seismic analysis of double-decker elevated water tank
Bilal Naeem Sheikh1
Ganesh Mahalle2
1P.G Student, Department of Civil Engineering, Gondwana, University Maharashtra, India. 2Professor of civil engineering department, Ballarpur Institute of technology, bamni, Maharashtra, India.
Published Online: January-February 2025
Pages: 18-21
Cite this article
↗ https://www.doi.org/10.59256/ijire.20250601003References
1.Gaikwad madhukar (REVIEW ON SEISMIC ANALYSIS OF ELEVATED WATER TANK)
2. Neha Pol-( SEISMIC ANALYSIS OF ELEVATED WATER TANK)
3.Vrushali Gujar (JAN 2020) Review on Seismic Analysis of Elevated Water Tank with Different Staging Configuration.
4.Dr. K. B. Prakash - September-(2023 )SEISMIC ANALYSIS OF ELEVATED WATER TANK.
5.Pradnya V. Sambary , D.M. Joshi-. February 2023 seismic analysis of RC elevated water tank
6.Manali Ugemuge june (2023) seismic analysis and design of circular elevated water tank for variation of H/D ratio and
bracing patterns.
7. L.Raghava Naidu (February 2019) seismic analysis of elevated water tank in different seismic zone.
8.Arjun Butala (2022) seismic analysis and design of elevated water tank for different stanging condition.
9.Sanket Nimbekar. A. (2020) Seismic response control of elevated water tank using base isolation.
10.Raoglu and A. Dogangun, “Effect of foundation embedment on seismic behavior of elevated tanks considering fluid- structure –soil
interaction”, Soil dynamics and earthquake engineering- ELSEVIER, (2007), (855-863).
11.HalilSezen and Livaoglu et al. “Dynamic analysis and seismic performance evaluation of above ground liquid- containing tanks”,
Engineering structures- ELSEVIER,(2008),(794-803)
12.A.I Gareane and Algreane et al, “Behavior of elevated concrete water tank subjected to artificial ground motion”, Electronic journal
of geotechnical engineering, (2008), Vol.16, (387- 406)., F. & Johnston, E. - Discusses buckling and slenderness in materials, providing
foundational knowledge.
13.IS:456-2000 : Code of practice for plain and reinforced concrete.
14. IS:875-1987(PART-2) : Design loads for buildings and structure.
15. IS:1893-1984 : Criteria for earthquake resistant design of structures.
16. IS:11682 : Criteria for design of RCC staging for overhead water tanks.
17.Double-decker elevated water tank is Designed and constructed by Gammon India in 1990 for Andheri Sports complex.
18. NMC(Nagpur Municipal corporation) the civic body has come up with first-of-its-kind proposal of constructing a double-decker
ESRs having 2.2 MLD capacity each
2. Neha Pol-( SEISMIC ANALYSIS OF ELEVATED WATER TANK)
3.Vrushali Gujar (JAN 2020) Review on Seismic Analysis of Elevated Water Tank with Different Staging Configuration.
4.Dr. K. B. Prakash - September-(2023 )SEISMIC ANALYSIS OF ELEVATED WATER TANK.
5.Pradnya V. Sambary , D.M. Joshi-. February 2023 seismic analysis of RC elevated water tank
6.Manali Ugemuge june (2023) seismic analysis and design of circular elevated water tank for variation of H/D ratio and
bracing patterns.
7. L.Raghava Naidu (February 2019) seismic analysis of elevated water tank in different seismic zone.
8.Arjun Butala (2022) seismic analysis and design of elevated water tank for different stanging condition.
9.Sanket Nimbekar. A. (2020) Seismic response control of elevated water tank using base isolation.
10.Raoglu and A. Dogangun, “Effect of foundation embedment on seismic behavior of elevated tanks considering fluid- structure –soil
interaction”, Soil dynamics and earthquake engineering- ELSEVIER, (2007), (855-863).
11.HalilSezen and Livaoglu et al. “Dynamic analysis and seismic performance evaluation of above ground liquid- containing tanks”,
Engineering structures- ELSEVIER,(2008),(794-803)
12.A.I Gareane and Algreane et al, “Behavior of elevated concrete water tank subjected to artificial ground motion”, Electronic journal
of geotechnical engineering, (2008), Vol.16, (387- 406)., F. & Johnston, E. - Discusses buckling and slenderness in materials, providing
foundational knowledge.
13.IS:456-2000 : Code of practice for plain and reinforced concrete.
14. IS:875-1987(PART-2) : Design loads for buildings and structure.
15. IS:1893-1984 : Criteria for earthquake resistant design of structures.
16. IS:11682 : Criteria for design of RCC staging for overhead water tanks.
17.Double-decker elevated water tank is Designed and constructed by Gammon India in 1990 for Andheri Sports complex.
18. NMC(Nagpur Municipal corporation) the civic body has come up with first-of-its-kind proposal of constructing a double-decker
ESRs having 2.2 MLD capacity each
Related Articles
2025
Iot-Based Power Theft Detector
2025
Comparative Analysis of Conventional and Diagrid Structural Buildings with Plan Irregularity
2025
The Role of C Language in Google, Adobe, and Mozilla Firefox Applications: Performance, Security, and Future Developments
2025
Seismic Analysis of Circular Building and Rectangular Building
2025
A Review on Implementation of 5S in Indian Culture during Diwali Festival
2025